IRMA TruPoint Blood Analysis system

IRMA TruPoint offers bedside testing that is accurate, reliable and self-contained.

Accurate

  • Precise results within two minutes
  • Lab quality accuracy
  • Comprehensive menu
  • Custom correlation

Reliable

  • Single-use cartridge for maintenance free convenience
  • Self-contained calibrant in each cartridge
  • Real-time, automatic electronic quality control

Self-Contained

  • All-in-one design is lightweight and battery-operated
  • On-board thermal printer documents results and test notes
  • Interactive touch screen

example graphic

Test Menu

Measured Values:

  • BG Cartridge: pH, pCO2, pO2
  • H3 Cartridge: Na+, K+, iCa, Hct
  • CC Cartridge: pH, pCO2, pO2, Na+, K+, iCa, Hct
  • H4 Cartridge: Na+, K+, Cl-, BUN, Hct
  • GL Cartridge: Na+, K+, Cl-, Glucose
  • CR Cartridge: Creatinine
  • LA Cartridge: Lactate

Calculated Values:

  • BG Cartridge: HCO3-, TCO2, BEb, BEecf, O2SAT
  • H3 Cartridge: tHb
  • CC Cartridge: HCO3-, TCO2, BEb, BEecf, O2SAT, tHb, iCa(N)
  • H4 Cartridge: tHb
  • CR Cartridge: MDRD-GFR

Consumable

  • Room Temperature Storage (Creatinine cartridge requires refrigeration)
  • Single-use cartridge
  • Calibration with every test
  • No external reagents or gases required
  • Closed sample introduction system
  • Easy to use

Cartridge Test Menu – Measured Values:

example graphic

 CC  BG  H3  H4  GL  CR  LA
pH       ?       ?
pCO2;       ?       ?
pO2       ?       ?
Na+       ?       ?       ?       ?
K+       ?       ?       ?       ?
Cl-       ?       ?
iCa       ?       ?
Glu       ?
BUN       ?
Hct       ?       ?       ?
Creatinine       ?
Lactate       ?

Cartridge Test Menu – Calculated Values:

 CC  BG  H3  H4  GL  CR
HCO3-       ?       ?
TCO2       ?       ?
BEecf       ?       ?
BEb       ?       ?
O2SAT       ?       ?
iCa(N)       ?
tHb       ?       ?       ?

Specifications

Reportable Ranges Measured:

 pH  6.000-8.000 pH units
 pCO2  4.0-200.0 mmHg (0.53-26.66 kPa)
 pO2  20.0-700.0 mmHg (2.67-93.33 kPa)
Na+ 80.0-200.0 (mM, mEq/L)
K+ 1.00-20.00 (mM, mEq/L)
Cl- 30.0-150.0 (mM, mEq/L)
iCa 0.20-5.00 mM (0.40-10.00 mEq/L; 0.80-20.00 mg/dL)
BUN 3-150 mg/dL (1.1-53.5 mM)
Glucose 20-500 mg/dL (1.1-27.8 mM)
Hct 10.0-80.0% (.100-.800 SI)
Creatinine 0.2-12 mg/dL (18-1061 µmol/L)
Lactate 0.30-12 mmol/L (2.7-108 mg/dL)

General Specifications:

Minimum Blood Sample Size 0.2mL from a syringe 0.125mL from the IRMA TruPoint Capillary Collection Device
Data Storage 200 patient test records 150 liquid QC records 100 electronic QC / Temperature test results
Cartridge Storage Temperature 15-30°C / 59-86°F
Creatinine Cartridge Storage Temperature 2-8°C / 35.6-46.4°F

Literature

  • IRMA TruPoint Quality Control Statement (English)
  • IRMA TruPoint User Manual (English)

Optional Accessories:

  • Barcode reader
  • idms™ data management software
  • Device Set configuration software

Connectivity:

Interface connectivity available through:

  • AegisPOC™
  • RALS®-Plus
  • TELCOR QML®

Quality Control:

  • Liquid Quality control performed using RNA® Medical Controls.